Who's Online
There currently are 5813 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
- BLOCK DIAGRAM
- DISASSEMBLY FOR REPAIR
- COMPONENTS DESCRIPTION
- MICROCOMPUTER'S TERMINAL DESCRIPTION
- CIRCUIT DESCRIPTION
- ADJUSTMENT
- PC BOARD
- SCHEMATIC DIAGRAM
- EXPLODED VIEW
- PARTS LIST
- SPECIFICATIONS
There are currently no product reviews.
;
Thanks for offering this item at such a good price. Proved handy in identifying the part I was looking for my set.
Thanks again.
;
This is the original manufacturers service manual, with detailed info on the circit boards, explosion drawings of all parts in assembly order, and tuning instructions. The only thing missing is the information on the dimensions of the various drive belts. mail me if you need them. gcrossman_at_aol.com
;
Ordered service manuel for a hard to find plasma tv - your company made it easy to find and purchase - I will use you again
Thanks for your help
;
This is a high quality manual with clear schematic and components layout diagrams ; with service procedure included.
;
This service manual for the Kenwood KT-990D was reproduced really well ,is very legible and manual is complete.Combined with the low price paid,in the future,I will be checking Owner-Manuals.com any time I need a manual.
KVT-910DVD/920DVD/930DVD/ 940DVD/960DVD
ADJUSTMENT
X86 Circuit Adjustment Specification (K, R, H type)
Item 1. Adjusting image detection coil L103 Adjustment Method & Value 1. Turn VR101 [RF-AGC] counter-clockwise as much as possible. 2. Impresss sDC2.0V to TP [IF AGC] (IC101 #36). 3. Input fo=45.75MHz Mod=1KHz AM60% Level=100dBµ to TP [IF] (CF1 #1). 4. Observe the waveform of TP [VIDEO] (IC101 #8) using an oscilloscope, and adjust L103 so that the output level is at the maximum.
Maximu
Condition � ANT no signal � If the waveform is clipped, raise the DC voltage somewhat. � AC range
2. Adjusting audio detection coil L101
1. Turn VR101 [RF-AGC] counter-clockwise as much as possible. 2. Input fo=41.25MHz non-modulated Level=94dBµ to TP [IF] (CF1 #1). 3. Connect a voltmeter to TP [SIF] (both ends of R107) and adjust L101 to 0V ± 0.01V. 1. Turn VR101 [RF-AGC] to clock-wide direction as much as possible. 2. Input RF signal 30dBµ 11CH color bar to ANT input terminal. 3. Audio (P/S-6dB) non-modulated. 4. Connect a voltmeter to TP [IC101 #12] and adjustVR102 [SMET] to 3.5V ± 0.05V. 5. Set RF signal 70dBµ and adjust VR101 [RF-AGC] so that the value of the voltmeter connected to TP [IC101 #12] is 4.6V ± 0.05V. 1. Connect frequency counter to PIN1 of CN5 [IC2 #7]. 2. Connect Pin3 [IC2 #8] of CN5 and Pin2 [GND]. 3. Adjust VR1 [15KHz] and set to 15734Hz ± 100Hz.
� ANT no signal
3. Adjusting S-METER VR102 4. Adjusting RF AGC VR101
� SlideVR101 so that AGC will not be effective at 30dBµ. � Be sure to conduct adjustment on the SMETER before adjusting RFAGC.
5. Diversity free-run frequency VR1
� ANT no signal