Who's Online
There currently are 5859 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Very quick and easy website to use and fast download of manual, quality of manual is excellent and will be pleased to use this service again in the future, thanks so much!
;
Easy and secure way to get a complete service manual of a vintage hifi component. Only some parts of the print copy are dificult to read. Nice price!
;
The manual is an excellent reproduction with complete schematics, made troubleshooting and repair a simple process.
;
Up to now you are the BEST! Prompt-efficient and so reasonable ! I have been after SONY service manual for quite some time !Thank you very much ! I can recomend your service to
all my collegagues ! V.Bergfield .
;
This is a very good quality print (scan) of the original SONY service manual. The original from Sony is on very thin paper. Nevertheless it is very clear and sharp and excellent readable. I'm very satisfied to have now this rare document. I've looking for it many years (infrequent). It contains very detailed circuit diagrams, exploded views, part lists, PCB view with good readable connection lines. Very recommended.
KTC-V500E/N/P
ADJUSTMENT
X25 Circuit Adjustment Specification (M : For the Other Markets) Item
1. Video detection co il adjustment L303
Adjustment method/Adjustment value
1. Turn VR301 [RF-AGC] fully to the right. 2. Apply DC2.0V to TP [IF AGC] (IC300 pin36). 3. Feed fo=38.0MHz, Mod=1kHz, AM60%, Level=100dBµ into TP [IF] (A100 pin8). 4. Observe the TP [VIDEO] (IC300 pin8) waveform on an oscilloscope and adjust L303 for maximum level.
Conditions
No ANT signal If the waveform is clipped, slightly increase the DC voltage. AC range
Maximum
2. Audio detection coil adjustment L300
1. Turn VR301 [RF-AGC] fully to the right. 2. Feed fo=31.5MHz, No Modulation, Level=94dBµ into TP [IF] (A100 pin8). 3. Connect a voltmeter to TP [SIF] (both ends of R314) and adjust L300 for 0V ± 0.01V.
No ANT signal
3. S-METER adjustment VR300 4. RF AGC adjustment VR301
1. Turn VR301 [RF-AGC] fully to the right. 2. Feed a 30dBµ CHINA 9CH color bar RF signal into the ANT input terminal. 3. Audio (P/S ratio -6dB) no modulation. 4. Connect a voltmeter to CN300 and adjust VR300 [SMET] so it reads 3.5V ± 0.05V. 5. Set the RF signal to 70dBµ and adjust VR301 [RF-AGC] so that the voltmeter connected to CN300 reads 4.8V ± 0.05V.
Postpone adjusting VR301 to prevent AGC having effect at 30dBµ. Ensure the RF AGC adjustment is performed after the S-METER adjustment. No ANT signal Test mode
5. Diversity free run frequency adjustment VR400
1. Connect a frequency counter to CN400. 2. Using the remote control unit TV/NAVI button, switch to adjustment mode. 3. Adjust VR400 [15kHz] so as to obtain 15625 ± 100Hz.