Who's Online
There currently are 6017 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
I'm very happy that you all are performing an incredible good job. Furthermore what you did is very useful for all people as me that have electronics as an hobby.Thank you!!!!!
;
Manual found fast and good quality, very helpfull service
;
8-17-12 Been using the sight for about 6 months. Fast Downloads and top quality
Manuels !
;
Everything was great, the manual, the response time, the simplicity of the order, and the
Price. The only thing that I could possible say on a negative note would be that the manual I ordered was more for a service tech. There were a lot of schematic diagrams that didn't help me solve the problem. However I would order again and recommend the web sight to others.
;
I'd been looking for this manual for awhile. Exactly what I needed - and at an excellant price. Thanks!
KDC-MP222 KDC-MP4023/G
MICROCOMPUTER�S TERMINAL DESCRIPTION
Truth table 1 PS1-0 L H(L) H H PS1-1 L L(H) H H PS1-2 L L L H AUDIO OFF ON ON ON P-CON OFF OFF ON ON P-ANT OFF OFF OFF ON
Truth table 2 PS2-0 L H (L) H PS2-1 L L (H) H ILLUMI OFF ON ON FM+B OFF ON OFF AM+B OFF OFF ON
Truth table 3 MOSW L H Hi-Z LO/EJ H H L H CD mechanism operation Load Eject Lo/Ej invalid truth Brake
Truth table 4 (destination setting) model KDC-MP222 KDC-MP4023 KDC-M4524/G/Y/GY destination TYPE2 K M (E) E/E2 destination ports TYPE1 0 0 1 TYPE0 0 1 0
TEST MODE
1. How to enter the test mode
While holding the Preset 1 and Preset 3 keys, reset the unit. � SYSTEM Q � BEEP � CRSC : OFF regardless of the presence of switching function. : Flat : When pressing any keys, the buzzer generates a beep at any time. � SYSTEM Q MENU : OFF
2. How to exit from the test mode
Reset the unit, ACC OFF, power OFF and Panel detached. (Note) The test mode cannot be terminated by momentary power down.
4. Special display in Tuner mode
When any of the following messages is displayed in Tuner mode, the F/E may be abnormal. � "TNE2P NG" : The EEPROM is set to the default (unstable values) because the F/E was shipped without passing through the adjustment process, etc. � "TNCON NG" : Communication with the F/E is not possible.
3. Initial status in the test mode
� Sources � Display � Volume � Loudness : ALL OFF : All segments are lit. : -10 dB (displayed as "30") : OFF