Who's Online
There currently are 6027 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Very helpfull information and I highly recommend this source for needed information about your products.
;
More than pleased with my prurchase, very good product for the price.
;
This is a good quality scan of the service manual which includes an assembly diagram, block diagram, schematic, and parts list. Exactly what is needed to repair my KR-V55R receiver.
;
Excellent concise manual. All needed information was included. Typeface and diagrams were clear. Very fair price considering what others are charging. Many thanks
;
Response is a little slow- I had to wait 12 hours to receive download link but it says that it may take up to 24hrs.
Manual is old and was not produced in PDF- scanned copy is exellent.
Overall- value for money- I recommend
DV-5700/DVF-R9050/R9050-S
ADJUSTMENT
No. ITEM INPUT SETTING OUTPUT SETTING ALIGNMENT POINT VR601 ALIGNMENT FOR Y-signal = 1000mV 30mV FIG. Connect the oscilloscope to 100% COLOR BAR DISC Y output with 75-ohms resistor. Output Mode: Interlace 100% COLOR BAR DISC Connect the oscilloscope to COMPOSIT output with 75ohms resistor.
1
Y,Cb,Cr LEVEL
FIG.1
2
Y LEVEL
VR600
COMPOSIT-signal = 1000mV FIG.2 30mV
You need the step 1and 2 before next step 3
3
CHROM LEVEL
Connect the oscilloscope to 100% COLOR BAR DISC COMPOSIT output with 75ohms resistor Connect the oscilloscope to 100% COLOR BAR DISC Y output with 75-ohms resistor. Output Mode: Progressive
VR602
Chrom-signal = 286mV 14mV Y-signal= 1000mV±30mV
FIG.2
4
Progressive Y, Cb, Cr LEVEL
VR800
FIG.1
IRE' Peak white [mV]
714 (100IRE)
714
white yellow
641
100
cyan 516 green 443 magenta 324 red
252
blue
127
black
54
1000mV 30mV 1000mV 30mV
286mV 0 ±14mV
Blank
0
4.7 s
-2.86
Y
-40
Sync. chip
Fig. 1
Fig. 2
26
|
|
|
> |
|