Who's Online
There currently are 6018 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Great product, helped me to restore vintage walkman cassette.
Just some pictures could be little bit more sharp and contrast
Thank you
;
I love older radio's and the service manuals that are sometimes hard to find. Was able to find a manual quite easily on this site.
;
Thank you for your shop manual! Your help was very useful - the device is repaired! Once again - Thank you! I wish you a successful business! Edward (Russia).
;
It was a great experience,instead of purchasing a new Stereo Amplifier ,in just minutes i repaired my old one and that was thaks to the manual I have purchased from you.
Thanks again.
Samuel Alter
;
Das ging ja sehr unkompliziert hat bestens geklappt und die Quallität ist auch noch gut.
Vielen Dank dafür.
CD-403/403-S/404/406/DPF-R3030/R3030-S/R4030/R4030-S/R6030
ADJUSTMENT
No. ITEM INPUT SETTINGS OUTPUT SETTINGS PLAYER SETTINGS ALIGNMENT POINTS ALIGN FOR FIG.
Open the tray (Normal mode), then turn the power off. While pressing the REPEAT key, turn the AC ON. (Test mode) Press the PLAY/PAUSE key, then confirm that the display is "03". On the power from 0.08 to 0.15 mW, when the diffraction grating is correctly aligned with the RF level of 1.0 Vp-p or more.
1
LASER POWER
�
Apply the sensor section of optical power meter on the pickup lens.
�
(a)
1. Load a disc on disc 1 tray. 2. Turn the power off. 3. While pressing the REPEAT. key, turn the power ON to enter the Test mode. Connect an oscilloscope as follows. CH1: Connect the DC voltmeter to CN3(pin3 and 4) on X32. Press the PLAY/PAUSE key, then confirm that the display is "05". Press the PLAY/PAUSE key, then confirm that the display is 03 or 05.
1
FOCUS ERROR BIAS
Test disc Type 4
FE BIAS VR1
Optimum eye pattern
2
LASER CURRENT CHECK
Test disc Type 4
-
0.5±0.2V
Note: Type 4 disc : SONY YEDS-18 Test Disc or equivalent. LPF: Around 47 k�+ 390 pF or so. Step 1~4 are in Test Mode.
(a) Laser power
0.08~0.15 mW
Pickup
Optical power meter